500kva 33 0.415 Kv Distribution Transformer
Want to know more about our products? Please contact us by email or phone.
Gnee Steel (Tianjin) Co., Ltd. is one of the most professional 500kva 33 0.415 kv distribution transformer manufacturers and suppliers in China. Welcome to wholesale customized 500kva 33 0.415 kv distribution transformer at competitive price from our factory. Good service and quality products are available.
GNEE Steel power distribution transformer
Basically, a distribution transformer is also known as a common kind of isolation transformer, and its main function is to alter the high voltage of the transformer from normal voltages like 240/120 volts to use in electric power distributions.
When it comes to the distribution system, there are several types of transformers out there. Including but not limited to single-phase transformers, three-phase transformers, pad-mounted transformers, pole-mounted transformers, and many more.
In general, these types of transformers are usually available in various sizes with different levels of efficiencies, and there is a difference in their insulating oil as well. The selection of these transformers relies on the equipment and also your budget.
distribution transformer manufacturers

The 500kva 33 0.415 Kv Distribution Transformer Technical Data
|
Rated Capacity: |
500 kVA |
|
Mode: |
S11-M-500 or according to requirements |
|
Primary Voltage: |
33kV |
|
Secondary Voltage: |
415V |
|
No Loading Loss: |
680±10% W |
|
Loading Loss: |
6516±10% W |
|
Impedance: |
6.5%±10% |
|
Tapping Method: |
online tapping or offline tapping |
|
Cooling method: |
ONAN |
|
Altitude: |
less than 1000m above the sea level |
The 500kva 33 0.415 Kv Single Phase Distribution Transformer Annual Maintenance Procedures
For the annual inspection, component maintenance and cleaning are the key focus:
1.Use soft cotton to clean the 500kva 33 0.415 kv distribution transformer bushings.
2.Annual inspection of OLTC (On-Load Tap Changer) is crucial. Ensure moisture levels and dielectric properties are at the appropriate levels for efficient operation. (Observe oil condition and sample moisture content (PPM) and dielectric strength (BDV). Low BDV and high PPM levels indicate the need for oil replacement.)
3.Tighten all connections of control and relay circuits at least once a year. Additionally, check if the indicator heaters are at standard spacing and performing as required. Clean the marshalling box at least once a year. (The marshalling box should be cleaned. Indicator heaters should also be checked in conjunction with the space functions.)
4.Clean control switches, alarm devices, and relays along with their circuits using the specified cleaning agents.
5.Check the operation of your news release equipment.
6.Check the oil levels on indicators and ensure they contain the required oil volume for operation.
7.Measure the resistance rating of ground connections and risers. Do this by measuring ground resistance with a ground resistance tester.
single phase distribution transformer

Hot Tags: 500kva 33 0.415 kv distribution transformer, China 500kva 33 0.415 kv distribution transformer manufacturers, factory, 500 KVA Distribution Transformer, 20000 KVA Distribution Transformer