What Is S960 Steel Plate?

S960 steel plate is a quenched and tempered (Q&T) high-strength structural steel produced under EN 10025-6, the European standard for flat products of high yield strength structural steels in the quenched and tempered condition. The number 960 in the designation is the minimum yield strength in MPa, roughly 2.7 times that of ordinary S355 structural steel. The strength is obtained by water quenching followed by controlled tempering rather than by alloy content alone, so plates combine a very high strength-to-weight ratio with controlled toughness and consistent through-thickness properties.

Typical delivered requirements for the Q&T condition are summarised below.

Property Requirement (EN 10025-6, S960)
Minimum yield strength ReH 960 MPa
Tensile strength Rm 980–1150 MPa
Minimum elongation A 12 %
Charpy V impact energy (longitudinal) 27 J minimum at the grade test temperature
Delivery condition Quenched and tempered (Q&T)

Grade Variants: S960Q, S960QL and S960QL1

The three variants differ only in guaranteed low-temperature impact toughness. They are otherwise identical in strength level and are ordered by selecting the toughness class required by the service temperature of the structure.

Grade Impact test temperature Typical service situation
S960Q 0 °C General structural and crane applications in moderate climates
S960QL −40 °C Cold-region structures, offshore and northern projects
S960QL1 −60 °C Arctic and low-temperature offshore service

Specifying QL or QL1 does not change the yield strength, but it does restrict the steelmaking and rolling route, so lead time and price step up with each toughness class.

Why Designers Specify S960

The main driver is weight reduction. Because allowable stress roughly scales with yield strength, a member designed in S960 can use a substantially thinner section than the same member designed in S355. That reduction in self-weight is carried through the whole load path: smaller foundations, lighter transport loads, lower crane capacity needed on site and less welding volume in some joints. S960 is therefore common in mobile cranes, concrete pump booms, high-reach equipment, trailer chassis, mining truck bodies and bridge strengthening work where added section depth is not available.

Welding and Fabrication Controls

S960 is weldable, but the strength level makes process control essential. Points that decide the outcome on the shop floor:

Heat input must be limited. Excessive heat input softens the heat-affected zone and reduces joint strength; too low heat input raises hardness and cracking risk.

Preheating is normally required for thicker plates and for high restraint joints; the preheat temperature is calculated from the carbon equivalent and combined thickness following EN 1011-2.

Low-hydrogen consumables and clean, dry joint preparation are mandatory. Moisture, rust and scale at the weld preparation are the usual cause of delayed cracking.

A qualified welding procedure specification (WPS) and procedure qualification record are required before production welding starts.

Undermatching consumables are frequently used for the root pass; the fill passes are selected according to the design joint strength rather than by matching the base metal strength blindly.

Ordering, Inspection and Documentation

Plates are normally ordered to EN 10025-6 with dimensional tolerances to EN 10029 and, where required, ultrasonic testing to EN 10160. Inspection documents follow EN 10204: a 3.1 certificate is issued by the manufacturer's inspection department, while 3.2 requires an independent inspection representative. For structural work under EN 1090, the certificate chain must be traceable from heat number to the delivered plate, and the marking on each plate has to carry the steel grade, heat number and the manufacturer's identifier. Hardness and tensile testing of the parent plate plus impact testing at the specified temperature are the routine acceptance tests; ultrasonic examination is added when through-thickness quality or internal soundness is specified.

Frequently Asked Questions

Q: Is S960 the same as S960QL?
A: No. S960 is the strength class; Q, QL and QL1 are toughness classes within that strength level, tested at 0 °C, −40 °C and −60 °C respectively.

Q: What is the minimum yield strength of S960 steel plate?
A: 960 MPa, with a tensile strength range of 980–1150 MPa under EN 10025-6.

Q: Can S960 be welded on site?
A: Yes, with a qualified procedure, controlled heat input, preheat for thicker sections and low-hydrogen consumables. Field welding of very thick or highly restrained joints is usually avoided.

Q: Which grade should be chosen for a cold-climate project?
A: Use S960QL down to about −40 °C and S960QL1 where −60 °C impact toughness is required.

Q: Can S960 be bent or formed?
A: It can be cold formed to generous radii; tight radii should be formed hot or by rolling with intermediate stress relief, because the material has limited residual ductility compared with S355.

Q: What documents should accompany an S960 delivery?
A: A certificate under EN 10204 in 3.1 or 3.2 form showing chemical composition, tensile and impact results, plus the plate marking that links the plate to its heat number.